CONTEC CMS60D Adult Pediactric Neonatal Handheld Pulse Oximeter

Instructions

Principle of the CMS60D Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc

Major Features

 

  1. Small in volume、light in weight and convenient in carrying
  2. Operation of the product is simple ,low power consumption
  3. Operation menu for the function setting
  4. SpO2 value display
  5. Pulse rate value display, bar graph display
  6. Pulse waveform display
  7. Screen brightness can be changed
  8. Pulse rate sound indication
  9. With review function
  10. With clock function
  11. With measured data overruns limits and low-voltage alarm function
  12. Battery capacity indication
  13. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function
  14. With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
  15. Real-time data can be transmitted to computers
  16. Connected with an external oximeter probe

Main performance

 

  • Display Mode: 1.8″ Color Display
  • Screen Resolution: 160*128
  • SpO2 Measuring Range:0%~100%(the resolution is 1%)
  • Accuracy: 70%~100%: ±2%, Below 70% unspecified.
  • PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
  • Accuracy: ±2bpm or ±2% (select larger)
  • Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
  • Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
  • Power Consumption: less than 100mA
  • Voltage: DC 2.6V~3.6V
  • Power Supply: Dry battery(2AA)
  • Battery working hour: The theoretical number is 44 hours.
  • Safety Type:Interior Battery, BF Type

Accessories

 

  • Sell in standard
    A user manual
    Adata line
    A disk (PC software)
    An oximeter probe
  • Sell in addition
    Other oximeter probe

Physical Identity

Dimension:110(L) × 60(W) × 23(H) mm
Weight:About 120g (with Alkaline battery(2AA))
Certification

CE , FDA

Category:

Reviews

There are no reviews yet.

Be the first to review “CONTEC CMS60D Adult Pediactric Neonatal Handheld Pulse Oximeter”

Your email address will not be published. Required fields are marked *